Three phase motors - Motor options
Motor protection
The following motor protection can be supplied:
- TW - PTC thermistor sensor
- TS - Thermorelay (closed)
- KTY - KTY sensor
- PT - PT1000 sensor
Anti condensation heating
- recommended for ambient temperatures below 0°C and at the presence of condensation water
- Motors: DM63..DA225
- Supply voltage: 230V
condensation drain hole
The condensation drain holes are located on the lower side of the motor, depending on the mounting position of the motor.
The condensation drain holes are closed at the factory and must be opened to drain condensate.
high inertia fan
- smooth start-up and braking behavior of the motors at mains operation due to additional inertia Jz
- Motors: DM63..DM112
| Motor | Jz [kgcm²] |
| DM63 | 9.7 |
| DM71 | 16 |
| DM80 | 28 |
| DM90 | 51 |
| DM100, DM90LB | 101 |
| DM112, DM100LA, DM100LE | 154 |
Protection cowl
The protection cowl prevents the penetration of foreign objects or liquids when the motor is mounted in vertical position.
| Motor | L4 | AC1 |
| DM63..DM80 | 26 | 122 |
| DM90..DM100 | 30 | 176 |
| DM112..DM132 | 30 | 220 |
| DM160 | 40 | 310 |
| DA180..DA225 | 43 | 240/338 1) |
1) Dimension for forced ventilation
Second shaft end WE and handwheel
The second shaft end can be used for fixing a handwheel or for radial force free transmission of the motor torque.
If radial forces apply to the second shaft end, please consult the manufacturer.
| D13 | D14 | D15 | E13 | E14 | E15 | E16 | E17 | F13 | G13 | |
| DM63 DM71 | 11 | 100 | M4 | 23 | 28 | 16 | 3.5 | 44 | 4 | 12.5 |
| DM80 DM90 DM100 DM112 | 14 | 160 | M5 | 30 | 35 | 22 | 4 | 44 | 5 | 16 |
| DM132 | 19 | 160 | M6 | 40 | 45 | 32 | 4 | 54 | 6 | 21.5 |
| DM160 | 38 | 250 | M12 | 80 | 85 | 70 | 5 | 98.5 | 10 | 41 |
| DA180 DA200 DA225 | 38 | 250 | M12 | 80 | 90 | 70 | 5 | 98.5 | 10 | 41 |
Position of terminal box
Example: 270C is for terminal box at 270, Cable lead in C
The position of other motor options (manual brake release, connection of forced ventilation, connection of encoder) is specified with the same method, independently, if different from position of terminal box.
Example: 90A, Manual brake release 270
Cable lead in
| normal | TW | B F |
B + TW B + F F + TW |
B + TW + F | |
| DM63..DM112 | 1xM25 | 2xM25 | 2xM25 | 2xM25+1xM16 | 1xM25+3xM16 |
| DM132 | 2xM32 | 2xM32+1xM16 | 2xM32 | 2xM32+2xM16 | 2xM32+2xM16 |
| DM160 | 2xM32 | 2xM32+1xM16 | 2xM32 | 2xM32+2xM16 | 2xM32+2xM16 |
| DA180 | 2xM40 | 2xM40+1xM16 | 2xM40 | 2xM40+1xM16 | 2xM40+1xM16 |
| DA200..DA225 | 2xM50 | 2xM50+1xM16 | 2xM50 | 2xM50+1xM16 | 2xM50+1xM16 |
- B
- Brake
- TW
- Motor protection TW, TS, KTY or PT
- F
- Forced ventilation
Plug connector HAN 10ES
- System: HAN 10ES (Harting)
- Motors: DM63..DM112
- Umax=500VAC, Imax = 16A
Plug connector M23
Motors: DM63..DM112
Power connector, Size 1, 8pole
Counterplug optional
Brake: Umax=250V
| Pin | 1 | PE | 3 | 4 | A | B | C | D |
| Signal | U | W | V | Brake + | Brake - | TW | TW |
Plug connector M40
Motors: DM132..DM160
Power connector Size 1.5, 8pole
Counterplug optional
Brake: Umax=250V
| Pin | U | V | W | PE | + | - | 1 | 2 |
| Signal | U | V | W | Brake + | Brake - | TW | TW |