Servo motors - Motor options

Brake COMBIPERM

Connection with power connector

Technical data

MotorBrakeMbr
[Nm]
JB
[kgcm²]
P20
[W]
t2
[ms]
t1=
[ms]
t11=
[ms]
WR0.1
[J*10^6]
WRmax
[J*10^3]
~kg
TA1, TA2BP0320.0681125620.415.30.2
TA3BP054.50.181235720.5880.4
TA4BP0690.541840720.89110.6
TA5BP07181.6624501031.29141
TA6BP08365.5626902232.9302
MotorBrakeMbr
[lb.in.]
JB
[lb in²]
P20
[W]
t2
[ms]
t1=
[ms]
t11=
[ms]
WR0.1
[J*10^6]
WRmax
[J*10^3]
~lb
TA1, TA2BP03180.21125620.415.30.4
TA3BP05400.531235720.5880.9
TA4BP06801.581840720.89111.3
TA5BP071594.8624501031.29142.2
TA6BP0832016.2726902232.9304.4

Brake COMBISTOP

Connection with power connector

Technical data

MotorBrakeMbr
[Nm]
JB
[kgcm²]
P20
[W]
t2
[ms]
t11=
[ms]
WR0.1
[J*10^6]
WRmax
[J*10^3]
~kg
TA3BF0270.318≤90≤257.54.81.5
TA4BF03160.720≤150≤6012.56.12.5
TA5BF04361.425≤220≤12019.110.64.8
TA6BF05703.530≤420≤6028.8328.3
Mbr
Static braking torque after completed run-in phase (20°C)
JB
Inertia
P20
Excitation rating at 20°C
t2
Release time, time from connecting the current to the beginning of torque decrease
t1=
Engaging time: Time from disconnecting of current until the rated torque is attained
t11=
Engaging delay time: Time from disconnecting of current until the torque rises
WR0.1
friction work until 0.1mm abrasion
WRmax
permissible friction work for emergency stop from 3000 1/min

The specified switching times apply to nominal clearance and nominal torque. It relates to average values and depends on the type of rectification and coil temperature.

Motor protection

The following motor protection can be supplied:

Additional inertia

To improve the control characteristics of the servo system with high external masses, the servomotors TA can be equipped with an additional inertia.

MotorJz
[kgcm²]
TA3S, TA3M2.6
TA41, TA4211
TA51, TA5228
TA61, TA62130

Electrical Connection

Motor TA1..TA5

Power connector Size 1, 8pole, Counterplug optional

Pin 1PE 34A B C D
SignalU WVBrake +Brake -TWTW

Motor TA6

Power connector Size 1.5, 8pole, Counterplug optional

Pin UVWPE + - 1 2
SignalUVW Brake +Brake -TWTW

F – Forced ventilation

Voltage/Frequency: 3~ 400V 50Hz

Rated current of forced ventilation: 0.14A

Power connector 4pole, Counterplug included

Pin 123PE
SignalUVW

Position of motor connection for geared motors

Example: Motor connection 90, Plug connector radial